Abstract

This paper presents a multi-variable DC-to-DC converter of the boost-boost type constituted by two cascaded boost converters in continuous conduction mode, each feeding an independent resistive load. A sliding mode feedback controller, based on the generalized proportional integral (GPI) approach, is developed for the regulation task. The feedback control scheme uses only output capacitor voltage measurements, as well as input signals represented by the switch positions. In addition robustness of the feedback scheme is tested by non-modeled sudden load resistance variations in the last resistive load. Experimental results verify theoretical predictions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.