Abstract

A novel approach to Le Fort I osteotomy is presented, integrating patient-specific implants (PSIs), osteosynthesis and cutting guides within a minimally invasive surgical framework, and the accuracy of the procedure is assessed through 3D voxel-based superimposition. The technique was applied in 5 cases. Differences between the surgical plan and final outcome were evaluated as follows: a 2-mm color scale was established to assess the anterior surfaces of the maxilla, mandible and chin, as well as the condylar surfaces. Measurements were made at 8 specific landmarks, and all of them showed a mean difference of less than 1 mm. In conclusion, the described protocol allows for minimally invasive Le Fort I osteotomy using PSIs. Besides, although the accuracy of the results may be limited by the small sample size, the findings are consistent with those reported in the literature. A prospective comparative study is needed to obtain statistically significant results and draw meaningful conclusions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.