Abstract

It has been suggested earlier that the incidence angle modifier K τα for low concentrating collectors with tubular absorbers could be factorised according to K τα ( θ t, θ l) ∝ K τα ( θ t,0) K τα (0, θ l, where θ tand θ l are the projected incidence angles in the transversal and longtitudinal projection planes, respectively. Ray-tracing calculations on low-concentrating CPC collectors with flat absorbers parallel to the cover show that a K τα factorisation overestimates the annual delivered energy from the collector by about 4–5%, when compared to calculations using the full incidence angle modifier. Data from outdoor testing has been used for characterization of incidence angle behaviour for a truncated CPC with a concentration of C = 1.56. Multiple linear regression analysis was used. This analysis technique makes feasible the determination of angular dependent incident angle modifiers and is an efficient tool to use for all collectors which cannot be characterised by standard equations of the incidence angle dependence.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.