Abstract
Phase change material (PCM) is an attractive solution for improvement of thermal performance in buildings, and have excited a vast amount of research in recent years. There are however practical challenges with ensuring adequate phase transitions of the PCM to exploit the passive heat storage benefits. Night ventilation (NV) with free cooling have surfaced as one of the most promising methods to properly utilize PCMs and maximize energy savings. This work deals with a novel spackling compound enhanced with microencapsulated PCM. The product is intended for use at inner walls and ceiling surfaces of buildings and is suited for new and retrofitting building applications. Ensuing former experimental studies, a validated simulation model is developed and used to study the PCM with natural and hybrid NV strategies in an office building during summer conditions in Oslo, Norway. Cooling load reduction and energy savings are analyzed with varying air flow rates of 0.5–5 air changes per hour (ACH) and 2–4 mm PCM layer thickness. It is shown how increasing air flow rates and PCM thickness greatly enhances energy performance, but at a diminishing rate. Although the NV alone can reduce the cooling load by 11.5% at 1 ACH, 40.2% at 3 ACH and 59.8% at 5 ACH, one can achieve further reduction up to 19.5%, 78.2% and 95.5% for the respective ACHs with 4 mm PCM. The natural NV provides more energy savings compared to the hybrid strategy. As energy requirement by fans increases with the increase of air flow rates in the hybrid strategy, the energy savings eventually start to reduce. The hybrid strategy can save 38% energy at most with 3 ACH, and the savings is increased to 50% with the inclusion of 4 mm PCM. On the other hand, the natural strategy saves 56% of energy at the same air flow rate, and 69% with 4 mm of PCM.
Highlights
Improvement of energy efficiency is one of the priority research areas for the construction engineers/scientists towards the mitigation of the socioeconomic challenges like climate change nowadays
The studied application of the material is in the range of 2–4 mm on walls and ceiling surfaces in office cubicles coupled with Night ventilation (NV) as a strategy to charge the Phase change material (PCM) during night time
The results reveal that being applied only in thin layers it yields a significant boost to the thermal inertia of the environment, slowing down and reducing the indoor temperature development throughout the hot period of the day
Summary
Improvement of energy efficiency is one of the priority research areas for the construction engineers/scientists towards the mitigation of the socioeconomic challenges like climate change nowadays. European Union (EU) aims to achieve climate-neutrality by 2050 and wants to lead global efforts in this way. A key part of the strategy is to maximize the energy efficiency of buildings [3]. The increasing amount of research findings shows that the incorporation of PCMs in building/construction materials is an effective solution in new constructions and in retrofit solutions [4]. PCMs are a promising passive cooling technology which can increase a building’s thermal mass in an effective way [5,6,7,8]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.