Abstract
For the determination of diffusion coefficients by using the model “diffusion into a plate” methodical examinations were carried out on samples of austenitic steel that had been nitrided in their marginal zones for 1.5 h at 1523 K. For recording of the concentration of N as a function of the distance from the surface electron-probe microanalysis (EPMA) and the precision determination of the lattice parameters by Kossel technique were applied. Both methods yield comparable results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.