Abstract
The proper cleaning procedure for reverse osmosis (RO) membranes holds the key to achieving sustainable operation of RO processes during long-term filtration such as the reclamation of wastewater. In this study, the most adequate cleaning protocol was tested for RO membranes fouled by the steel wastewater. X-ray photoelectron spectroscopy (XPS) analysis of the fouling layer revealed the presence of the aromatics, aliphatic hydrocarbons, metallic oxides and hydroxides. An integrated cleaning procedure was developed for flux recovery. That is, metal chelating agent (MCA) plus alkaline-oxidant cleaning procedure consisting in one cleaning stage or two cleaning stages in series. MCA cleaning with 2 mM disodium ethylenediaminetetraacetate (Na2-EDTA) solution followed by alkaline-oxidant cleaning with 5 mM NaOCl+NaOH/pH 12.0 solution provided the maximum cleaning efficiency.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.