Abstract

A gas sensor system based on the surface plasmon resonance (SPR) effect in a 44 nm Au layer was studied. The usability of this sensor system was investigated for several analyte gases and gas mixtures which are interesting due to their flammability, toxicity or greenhouse effect. The SPR effect of gold was measured in nitrogen and compared with the gaseous alkane series which caused a shift of the position of the SPR effect. For in situ measurements, the phase shift Δ at the SPR angle ( Ψ minimum) in the analyte gas mixtures was measured for investigated gases in comparison with nitrogen. With this method, detection limits of different gases could be determined, which lie in a range interesting for safety engineering. Furthermore the aging effect of the gold layers which leads to loss in sensitivity of the sensor was investigated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.