Abstract
The accuracy of maximum entropy reconstruction of Z-contrast STEM images has been evaluated with the effects of experimental variables and noise taken into account by the means of image simulation. As the specimen contains atom species of greatly different atomic numbers, special attention is given to the reliability of the position and composition of lighter atoms that are determined from Z-contrast images in the presence of heavier atoms. When the noise is moderate (SNR >2.5), the position of atom columns can be measured within an accuracy of 0.03 nm. With a higher signal-to-noise ratio (SNR >5) the composition of lighter atoms can be resolved reliably from the Z-contrast images. However, when image noise increases, the relative intensity of lighter atoms may deviate from the actual value in the specimen object function.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.