Abstract
Heat exchanger networks in steam systems are traditionally designed to operate in parallel. Coetzee and Majozi (Ind. Eng. Chem. Res. 2008, 47, 4405−4413) found that by reusing steam condensate within the network the steam flow rate could be reduced. This was achieved by restructuring the networks into a series design, with the consequence of greatly increasing the pressure drop of the system. The boiler return condensate temperature was also reduced, which was found to decrease the boiler efficiency. Maintaining the boiler efficiency has been considered in the first two papers in this series, and pressure drop is introduced in this paper. The formulations from the previous two papers are used to find the minimum steam flow rate for a HEN while maintaining the boiler efficiency. The network exhibiting the minimum pressure drop for this flow rate is then designed using the critical path algorithm. The boiler efficiency is maintained using the constraints explored in papers I (Ind. Eng. Chem. Res. DOI: 10.1021/ie1007008) and II (Ind. Eng. Chem. Res. DOI: 10.1021/ie1008579) of this series. The minimum pressure drop for the network exhibiting the minimum flow rate found in paper I was 344.4 kPa; however, the flow rate was reduced by 29.6% as shown in paper I.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.