Abstract

Microwave measurements and machine learning algorithms are presented to estimate metal ion concentrations in drinking water. A novel block loop gap resonator (BLGR) as a microwave probe is designed and fabricated to estimate Pb ion concentrations in city water as low as 1 ppb with an rms error of 0.18 ppb. No physical contact between the BLGR probe and the water sample allows on-site/in situ continuous detection of ppb-level metal ion concentrations. The $S_{11}$ raw data (amplitude and phase) from the BLGR are used to classify and estimate metal ion concentrations using a support vector regression algorithm. The performance of the proposed method to estimate Pb concentrations in the presence of interfering metal ions (Cu2+, Fe3+, and Zn2+) is also evaluated, and it is found that the average measurement error remains less than 13%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.