Abstract

A new time domain static network model of a three phase in duction motor with squirrel cage rotor is presented. Simulation of the dynamic behaviour of a machine fed through static power control equipment containing switching devices of one kind or another can be conveniently achieved using this model. The pro cedure is simple and can be applied, with considerable flexibility, to any system containing one or more induction machines. The model is inherently capable to account for iron losses as well. It is also suited for simulation of machine dynamics with un balance introduced in the stator electrical circuits by a fault, pro vided the structure of the windings remains unaltered. A similar network model can be derived to represent a machine with an asymmetrical internal fault which splits one or more stator phases into multiple sections with or without interconnections. A pre viously published model of a triac has been improved (Ghani 1981).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.