Abstract

In this paper the effects of temperature on partial discharge (PD) activity taking place inside a spherical void in epoxy resin system are studied. Indeed, some experimental tests previously performed on specimens, having different void shapes, under multi-stress condition of temperature and voltage, have shown very different PD amplitude distributions at temperatures higher than ambient. However, this phenomenon cannot be explained only by taking into account the different thermobaric conditions of the enclosed gas. In consequence of the general physical inaccessibility of such voids, a study is here performed using a numerical model based on an evolutionary optimization algorithm. This is used to evaluate the range values for the physical parameters of the insulating system influencing the observed changes in PD activity. Finally, comments are presented about the adopted criteria by which the comparison between the experimental data and the simulated ones is performed, and about the interpretation of the dependence on temperature of the experimental PD.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.