Abstract

AbstractAppropriate installation design of soil water monitoring equipment is necessary to ensure the meaningful interpretation of the resultant data. For example, although piezometers are widely used in monitoring positive pore water pressures, the limits on the shape factor of the system in terms of the ceramic tip and filter design have not been fully studied. The filter design boundary conditions are investigated here using a finite element analysis, in which threshold ceramic tip and filter characteristics (permeability and dimensions) are identified. From the modelling results, it is possible to select the most suitable design installation.