Abstract

Textile finishing industry wastewater often contains high concentrations of surfactants. Non-ionic surfactants like alcohol ethoxylates are among the most used surfactants and are discharged from batch-processes in widely varying concentrations. The anaerobic biomass and especially methanogenic microorganisms have been shown to be inhibited by surfactants. To protect these microorganisms from irreversible inhibition a measurement of the surfactant concentration is useful for the process control, but most analytical methods are too complicated and expensive for an on-line process control. It was shown that the titration of non-ionic surfactants is possible in the presence of biomass and in wastewater from textile wet processes using the Metrohm NIO-electrode. Titration and sampling were successfully performed with standard equipment. The software used for the process control of a lab-scale anaerobic treatment plant was also used to evaluate the obtained titration curves. This allowed performing the titrations without using a more expensive titrator.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.