Abstract

AbstractA fast on‐line method for measuring the monomer conversion of a styrene batch polymerization reaction with near‐infrared spectroscopy (NIR) has been developed. Multivariate calibration was performed, using polymer samples having temperatures around the set point of the batch reactor (75–85°C) and monomer conversions up to 35%. The calibration model was built in such a way that the effect of the temperature on the predicted conversion of the sample was minimized. The method was validated in a number of batch runs. In these runs, the batch temperature and molar mass distributions of the polymer were varied. At‐line size‐exclusion chromatography was used as a reference method for measuring the monomer conversion. Results show that on‐line conversion monitoring with NIR offered overall an excellent accuracy (∼ 0.32% conversion). For high and low monomer conversions a small bias in the predicted conversion is present. The method proved to be insensitive to both relative large changes (10°C) of the batch temperature and to considerable changes of the molar mass distribution of the polymer. © 2002 Wiley Periodicals, Inc. J Appl Polym Sci 84: 90–98, 2002; DOI 10.1002/app.10241

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.