Abstract

Capillary electrophoresis (CE) with on-line direct chemiluminescence (CL) detection was first used in detecting protocatechuic aldehyde (PAH) and protocatechuic acid (PA) in their pharmaceutical preparations. It was found that the weak CL produced from the reaction of luminol with ferricyanide in an alkaline solution was strongly increased by PAH and PA which was separated by CE. Parameters affecting separation process and CL detection have been examined in detail. Under the optimum conditions, the baseline separation of PAH and PA was obtained within 6 min. The relative standard deviation (R.S.D.) for the analysis of PAH and PA was less than 1.1% for the migration time and 1.6% for the peak height. The detection limits ( S/ N = 3) of PAH and PA were 7.0 × 10 −8 M and 5.0 × 10 −8 M, respectively. The proposed method has been satisfactorily applied to the determination of PAH and PA in Salivia miltorrhrza pharmaceutical preparations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.