Abstract

Abstract Corrosion rate monitoring based on electrochemical methods is shown to provide an adequate tool for the fast and accurate determination of on-line corrosion rate in industrial electrolytic environments. Case histories, concerned with desalination plants and cooling tower water circuits, show that instantaneous corrosion rate measurements by the linear polarisation technique, combined with exposure of coupons, provide an efficient tool for optimising the technical-economic operation of the plant, and for determining the influence of the operating parameters on corrosion, thereby contributing to improved plant performance and efficiency.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.