Abstract
Overall cooling effectiveness was determined for a full-coverage effusion cooled surface which simulated a portion of a double wall cooling gas turbine blade. The overall cooling effectiveness was measured with high thermal-conductivity artificial marble using infrared thermography. The Biot number of artificial marble was matched to real gas turbine blade conditions. Blowing ratio ranged from 0.5 to 2.5 with the density ratio of DR = 1.5. A variation of cooling arrangements, including impingement-only, film cooling-only, film cooling with impingement, and film cooling with impingement and pins, as well as forward/backward film injection, was employed to provide a systematic understanding on their contribution to improve cooling efficiency. Also investigated was the effect of reducing wall thickness. Local, laterally averaged, and area-averaged overall cooling effectiveness were shown to illustrate the effects of cooling arrangements and wall thickness. Results showed that adding impingement and pins to film cooling, and decreasing wall thickness increase the cooling efficiency significantly. Also observed was that adopting backward injection for thin full-coverage effusion plate improves the cooling efficiency.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.