Abstract

To investigate distribution of the vertical temperature gradient of a closed steel box girder under solar radiation, specifications in four major codes on the vertical temperature gradient of a main girder or steel box girder in China and other countries are first compared. Then, temperature measurement is carried out inside a steel box girder bridge. It was found that under the effect of hot weather and strong solar radiation, the temperature rose rapidly on the deck overlay and reached its maximum at around 14:00, while the maximum temperature of the deck was recorded at around 16:00. Notable temperature differences between the deck and bottom plate occurred from 14:00 to 18:00, with the maximum value of 16.8℃ presented at around 14:30. It was also found that the positive vertical temperature gradient showed nonlinear distribution, and the girder top had a larger positive temperature difference but a minor negative temperature difference. A suggested pattern of vertical temperature gradient was fitted using a four-broken-line, which is in line with specification in the Eurocode 1.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.