Abstract
The poor thermal conductivity and low elongation-to-break ratio of titanium lead to the development of extreme temperatures (in excess of 550 °C) localized in the tool–chip interface during machining of its alloys. At such temperature level, titanium becomes highly reactive with most tool materials resulting in accelerated tool wear. The atomization-based cutting fluid (ACF) spray system has recently been demonstrated to improve tool life in titanium machining due to good cutting fluid penetration causing the temperature to be reduced in the cutting zone. In this study, the cutting temperatures are measured both by inserting thermocouples at various locations of the tool–chip interface and the tool–work thermocouple technique. Cutting temperatures for dry machining and machining with flood cooling are also characterized for comparison with the ACF spray system temperature data. Findings reveal that the ACF spray system more effectively reduces cutting temperatures over flood cooling and dry conditions. The tool–chip friction coefficient indicates that the fluid film created by the ACF spray system also actively penetrates the tool–chip interface to enhance lubrication during titanium machining.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.