Abstract
In this work the Minimum Error Profile (MEP) algorithm (Wahl et al., 2002) is applied to control of temperature profile in an Autothermal Reactor with Internal Counter-current Heat Exchange (ARICHE). Measurements of catalyst temperature at points along the reactor length form the basis on which the rest of the reactor states are estimated through an Extended Kalman filter. These state estimates are used to calculate the control actions necessary to drive the reactor optimally to the set point given by the MEP calculation. When subjected to sinusoidal variations in inlet compositions a LQR using the MEP as set point shows a superior performance when compared with controlling to a fixed steady state profile. In the case study presented, which has the potential for reaction run-away, this translates into safer control of the system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.