Abstract

This study is performed to investigate the temperature sensitivity of SU-8-based triple-arm Mach–Zehnder interferometer (MZI) and straight waveguide. The proposed SU-8 2000-based rib waveguides are fabricated on a silicon wafer with 1.5-μm SiO2 thermal oxide layer. SU-8 layer of desired thickness is spin-coated onto the silicon wafer followed by patterning of the SU-8 waveguides. Temperature sensitivity of both waveguides is evaluated using the same heating source and under the same environmental conditions. Measurement results show that complex triple-arm MZI having different arm lengths offers a less linear sensitivity compared to the simple straight waveguide.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.