Abstract

A library of 36 L-amino acid anilides, which are potential selectors for chiral HPLC, was synthesized in solution and attached to functionalized macroporous polymer beads. The best selector from the library was identified by a deconvolution process using the HPLC separation of several racemic N-(3,5-dinitrobenzoyl)-alpha-amino acid alkylamides as a probe. In each deconvolution step, a series of chiral stationary phases (CSPs) containing a subset of the amino acid anilide selector library was screened for enantioselectivity. After the best CSP was chosen, the library was further deconvoluted until the single best selector was found. The highest selectivity was obtained with a L-proline-1-indananilide that exhibited alpha values up to 23 under normal-phase HPLC conditions. In addition, six CSPs were prepared using individual selectors from the library, and screening results indicate that the deconvolution process indeed led to the most selective receptor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.