Abstract

This chapter presents a reliability model of the TMR (Triple Modular Redundancy) system based on analogue measurement channels. While reliability modelling of the standard TMR system (based on digital channels) has been well described in many previous publications, an applicable reliability solution for analogue measurement channels is still missing. First, the structure of analogue measurement channel is described in this chapter. Then, the reliability model of the wiring system is introduced. Next, the standard TMR model is presented and its reliability model is mentioned. An analogue TMR measurement channel system is introduced and its reliability model based on Markov processes is presented. Then the reliability model of the communication channel is described. Finally, the reliability of this model is analytically calculated and the solution is applied to an example.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.