Abstract

A dual inductively coupled plasma (ICP) system in which a remote ICP (upper ICP) with small volume is attached to a main ICP (lower ICP) is developed. Two ICP antennas are connected in parallel and a variable capacitor Cvar is installed in series at the end of the main ICP antenna. By adjusting the capacitance of the variable capacitor, the plasma densities and the electron temperatures in the remote region and the main region are controlled. The electron energy distribution functions (EEDFs) and plasma potential from the EEDFs are measured along z axis. It is found that there is a potential dip in the midway of two ICP antennas and the potential dip is formed to keep two plasmas quasineutral. In two regions, the EEDFs in high energy range are almost same (nonlocal) but they are different in low energy range because low energy electrons cannot overcome the potential dip.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.