Abstract

In this paper, change of flow patterns during the simultaneous flow of high viscous oil and water through the sudden contraction and expansion in a horizontal conduit has been studied. It is noted that these sudden changes in cross-section have a significant influence on the downstream phase distribution of lube oil–water flow. The observation suggests a simple technique to establish core flow as well as a way to prevent pipe wall fouling during the transportation of such oil. A number of interesting differences have been noted during low viscous oil–water flow through the same test rigs. While several types of core annular flow are observed for the former case, a wider variety of interfacial distribution characterizes kerosene–water systems. The pressure profiles during the simultaneous flow of lube oil and water through the sudden contraction and expansion are also studied and compared with low viscous oil–water flows. The pressure profiles are found to be independent of liquid viscosity and the loss coefficients are observed to be independent of flow patterns in both the cases.