Abstract
AbstractDifferent ways of reducing, calculating or measuring the ohmic component, the IR-drop, involved in potential measurements on cathodic protection installations are discussed. The measuring methods that seemed best suited for field usage have been tested in the laboratory as well as in measurements on buried, cathodically protected tank installations. The measuring methods chosen were the well known recorder method and the earth megger method, the later not having been described before. The results obtained with these methods were compared with those obtained with the oscilloscope method.It was established that both methods when used for measurements on steel structures give too high an IR-drop but that the magnitude of the error was dependent on the quality of the coating. When applied to buried structures having a poor coating the recorder method results are 25–30% higher, while the earth megger results are 10–15% higher, than those obtained by the oscilloscope method. The field investigations als...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.