The paper compares two methods for ohmic losses calculation in switch-mode power supply transformers: Dowell's 1D approach and 2D finite element method simulations (validated by measurements). Dowell's method underestimates losses at the fundamental frequency for foil windings, whereas harmonic losses are generally overestimated (depending on conductor type). More significant differences are found with high leakage inductance transformers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.