Abstract

Objective To investigate the effectiveness and safety of office hysteroscopic metroplasty by diode laser for the treatment of septate uteri. Study design We performed a prospective cohort study including 41 nulliparous women diagnosed with septate uterus and a history of primary infertility or recurrent miscarriage. All patients underwent hysteroscopic metroplasty for the treatment of the uterine septum, which was performed in-office setting using a 4.3 mm continuous-flow hysteroscope and a 15-watt diode laser at 1470 nm. Surgical and reproductive outcomes after 2 years of follow-up are reported. Results The procedure was well tolerated by 93% of patients. No surgical complications were reported. Thirty women out of 38 (78.9%) became pregnant: 17 (56.7%) pregnancies were spontaneously conceived, and 13 (43.3%) were obtained with assisted reproductive techniques. Twenty-four (80%) of the 30 pregnant women had a live birth, with a cumulative live birth of 63.2% among the 38 women (95% CI: 45.9–78.2%). There were no cases of post-partum hemorrhage or uterine rupture among 14 (58.3%) women who had vaginal deliveries. Conclusion Office hysteroscopic metroplasty for septate uterus using diode laser appears to be a feasible and safe alternative to other available techniques and has sufficient efficacy in terms of reproductive outcomes to be considered for further investigations.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call