Abstract

Recently, we implanted an apicoaortic conduit off-pump in three high-risk patients with severe aortic stenosis. A muscle-coring device was utilized to create the apical outflow tract followed by insertion of a rigid apical connector. A valved conduit was then connected to the descending thoracic aorta and to the apical connector graft. A stentless porcine bioprosthesis was implanted in two patients and a stented valve in one. The left ventricular (LV)-aortic gradients were reduced from a mean of 66 to 28 mmHg. With modification of an existing technique, apicoaortic conduit insertion can be performed safely off-pump. This technique can be applied to complex forms of LV outflow obstruction and high-risk patients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.