This paper first explains the necessity of off-line parameter identification of permanent magnet synchronous motors, and then introduces the identification methods and principles of the stator resistance, stator d/q axis inductance and back-EMF coefficient of permanent magnet synchronous motors. An identification method of stator d/q axis inductance injected with high frequency voltage is proposed. Finally, based on the MBD development model, the proposed identification method is modeled by Matlab/Simulink and the code is generated for experiments. The results verified the accuracy and feasibility of the proposed method well.