Abstract
To evaluate ocular biomechanical metrics given by the CorVis ST (Oculus, Inc., Berlin, Germany) in a population of healthy Brazilian patients. An observational and cross-sectional study involving 1 eye randomly selected from 90 healthy patients. Studied parameters (including deformation amplitude, first applanation time, highest concavity time, second applanation time, first applanation length, second applanation length, curvature radius highest concavity, curvature radius normal, velocity in, and velocity out) derived from the CorVis ST were correlated to central corneal thickness from the Pentacam (Oculus, Inc.). Differences between data on the basis of gender were evaluated. Mean patient age was 35.80 ± 12.83 years (range: 21.07 to 78.84 years). Mean central corneal thickness was 547.50 ± 32.00 μm (range: 490 to 647 μm) and mean spherical equivalent refraction was -3.29 ± 3.69 diopters (range: -9.50 to +10.37 diopters). Mean deformation amplitude was 1.05 ± 0.08 mm (range: 0.91 to 1.26 mm). Highest concavity time was 18.38 ± 0.93 ms (range: 16.95 to 21.07 ms). Intraocular pressure was 16.43 ± 2.15 mm Hg (range: 11.50 to 21.0 mm Hg). First applanation time was 8.32 ± 0.33 ms (range: 7.53 to 9.12 ms) and second applanation time was 23.80 ± 0.44 ms (range: 22.76 to 24.95 ms). First applanation length (max) was 2.07 ± 0.38 mm (range: 1.20 to 3.10 mm) and second applanation length (max) was 2.37 ± 0.47 mm (range: 1.33 to 4.12 mm). Curvature radius highest concavity was 11.09 ± 2.06 mm (range: 7.58 to 15.98 mm) and curvature radius normal was 7.59 ± 0.67 mm (range: 6.82 to 11.02 mm). Velocity in was 0.21 ± 0.05 m/s (range: 0.16 to 0.72 m/s) and velocity out was -0.33 ± 0.07 m/s (range: -0.72 to -0.20 m/s). Studied parameters were not associated with gender. Eight of 11 ocular biomechanical metrics given by the CorVis ST were associated with central corneal thickness, but the influence of central corneal thickness on these measurements was low.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of refractive surgery (Thorofare, N.J. : 1995)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.