Abstract

Transvenous laser lead extraction (TLE) for cardiac implantable electric devices (CIED) is a challenging procedure especially if performed in octogenarians. In this study we evaluated the safety and efficacy of transvenous laser lead extraction in elderly patients. This is a retrospective study of octogenarian patients who underwent laser-assisted lead extraction (LLE) (GlideLight laser sheath, Philips, San Diego, USA). 270 Consecutive patients were included. Patients were divided into two groups. Octogenarian group and non-octogenarian group. The Data was gathered from patients treated between September 2013 and January 2020 and is retrospectively analyzed. Of 270 consecutive patients, 38 (14.0%) were 80 years old or more. The total number of the extracted leads was 556 among which 84(15.0%) from the Octogenarian group. From these leads were 155 single coil leads, 82 dual coil leads, 129 right ventricular pacing leads, 155 right atrial leads, and 35 left ventricular leads. In the Octogenarian group the number of removed leads was as follows: 13 single coil leads, 10 dual coil leads, 28 right ventricular pacing leads, 28 right atrial leads and 5 left ventricular leads. No mortality was recorded in the Octogenarian group. One patient in the YG suffered from a superior vena cava tear and one patient suffered from pulmonary embolism. In octogenarian laser assisted lead extraction patients is a safe and effective procedure. No increase in morbidity, mortality or perioperative complication could be recorded in this group. Age should not be a limiting factor to perform this procedure.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call