A simple and reliable method based upon impregnation of Cyanex302 on octadecyl bonded silica membrane disk has been developed for separation and atomic absorption spectrometric determination of nickel. The influence of various parameters like aqueous phase pH, flow rate and volume of eluent were investigated systematically to optimize the conditions for quantitative sorption and desorption of nickel. The break through volume for nickel was greater than 1.0 dm 3, enrichment factor more than 100 and a detection limit of 2.1 μg dm −3 was achieved. The method applied for detection of nickel in tap water and effluent sample had a relative standard deviation (R.S.D.) of 0.4%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.