Abstract

BackgroundThis paper aims to investigate the occurrence and removal characteristics of phthalate esters from bottled drinking water using silver modified roasted date pits. Three adsorbents, namely roasted date pits (RODP), silver-modified roasted date pits (S-RODP), and activated carbon (AC) were used to investigate their adsorption characterizations in removing dimethyl phthalate (DMP), diethyl phthalate (DEP), dibutyl phthalate (DBP), butyl benzyl phthalate (BBP), di-2-ethylhexyl phthalate (DEHP), and di-n-octyl phthalate (DNOP) from the collected bottle water samples.MethodsThe occurrences of the phthalate esters in the collected bottled water samples were carried out at different temperatures (30, 50, and 60 °C), and analyzed using gas chromatography-mass spectrometry analysis - selected ion monitoring. Batch adsorption isotherms were used to study and establish the efficiency of such adsorbents in removing phthalate esters, in which they describe the adsorbent-adsorbate interaction systems. Adsorption efficiency of the various adsorbents was investigated by using different adsorbent masses (0.05 g, 0.10 g, and 0.15 g) and temperature (30 °C, 50 °C, and 60 °C). Different physical and chemical characterizations were studied using scanning electron microscopy (SEM), Fourier transform infrared (FTIR), Brunauer-Emmett-Teller (BET) surface area, pore radius, and pore volume.ResultsThe results indicated that the most abundant phthalate esters were DMP followed by DEP under 30 °C; however, DNOP was not detected in any of the tested water samples, except for one sample under 30 °C with a concentration of 0.031 μg/mL. The obtained results showed that phthalate esters leaching to the bottled drinking water were affected by storage temperature. The phthalate esters levels were increased with increasing the temperature to 60 °C. It was concluded that the ability of S-RODP for the adsorption of phthalate esters was better than the removal percentage obtained by AC and RODP. The removal percentage was increased from 90 to 99% by increasing the temperature from 30 to 50 °C and then decreased to 92.3% at 60 °C.ConclusionRODP was successfully used as an effective adsorbent for phthalate esters removal from drinking water. However, S-RODP has the highest removal abilities than other adsorbents due to the newly formed functional groups on its surface.

Highlights

  • The increased consumption of plastics in our daily lives is growing up

  • This paper aims to investigate the presence of phthalate esters in bottled water from different bottled water brands using gas chromatography-mass spectroscopy (GC-MS)

  • All sampled bottled waters were of the same size (1.5 L), and all samples were packed within Polyethylene terephthalate (PET) plastic bottles

Read more

Summary

Introduction

The increased consumption of plastics in our daily lives is growing up. According to Laville and Taylor [25], around a Nowadays, PET is the most widespread material for the production of water bottles, as the world witnessed a surge in the usage of PET bottled water due to the low productionJ Environ Health Sci Engineer (2021) 19:733–751 cost, ease of transport, as well as its size, and strength. The source of phthalate in plastic bottled water had gained an increased concern. It either could be present from the recycling of PET plastics, water resources before bottling or leached from the bottle material into the water [18]. Various organizations had set certain limits for the concentrations and levels of phthalates in drinking water due to their harmful effect on human health. Namely roasted date pits (RODP), silver-modified roasted date pits (S-RODP), and activated carbon (AC) were used to investigate their adsorption characterizations in removing dimethyl phthalate (DMP), diethyl phthalate (DEP), dibutyl phthalate (DBP), butyl benzyl phthalate (BBP), di-2-ethylhexyl phthalate (DEHP), and di-n-octyl phthalate (DNOP) from the collected bottle water samples

Objectives
Methods
Results
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call