Abstract

PurposeWater-bearing instruments and treatments in dental units produce aerosols originating from the dental unit waterlines (DUWLs), which are often microbially contaminated. Particularly, the presence of Legionella mainly realized as aerosols leads to a risk of infection in patients and dental staff.MethodsHere, we record the general bacteriological status of DUWLs in Germany and investigated the prevalence of Legionella spp., with a focus on identification and occurrence of distinct species considering the various aspects of dental practice such as dental chair equipment, disinfection methods, and temperatures.ResultsOut of 3789 water samples of 459 dental practices, collected in the years 2019 and 2020, 36.4% were Legionella positive with predominance of L. anisa (97.89%) identified by MALDI-TOF biotyping. L. pneumophila was detected very rarely. Risk factor analysis revealed that temperatures >20°C are a significant factor for increased Legionella colonization.ConclusionIn order to minimize the risk of infection, routine monitoring of the water quality in dental chair units is recommended with regard to general microbiological loads and to the presence of Legionella as opportunistic pathogen as well as the regular application of routine disinfection procedures.