Abstract

In 119 patients referred for upper gastrointestinal endoscopy, the faecal blood loss was determined by a 51Cr method and 7 chemical tests. For patients with negative upper endoscopy (no. = 8), atrophic gastritis (no. = 30), gastric ulcer (no. = 31), or gastric cancer (no. = 23), the median 51Cr-determined faecal blood loss was 0.51, 0.61, 0.83, and 2.68 ml/24 h, respectively. For all chemical tests, the results were highly influenced by the upper time limit for positive reaction. Mixing of faecal specimens before testing did not prove essential. By repeated analyses of faecal samples stored for 3 days, the benzidine test showed a decreased sensitivity (p less than 0.01), whereas Fecatwin and Fecatwin sensitive showed an increased number of positive tests (p less than 0.01). Of cases of gastric cancer, tetramethylbenzidine tests including Hemo-Fec Test, benzidine test, Fecatwin sensitive, Hemoccult II, and Fecatwin could detect about 85%, 80%, 60%, 55%, and 30%, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.