In this paper we consider a model-based fault detection and isolation problem for linear time-invariant dynamic systems subject to faults and disturbances. We use a state observer scheme that cancels the system dynamics and defines a residual vector signal that is sensitive only to faults and disturbances. We then design a stable fault detection and isolation filter such that the ℋ∞-norm of the transfer matrix function from disturbances to the residual is minimised (for fault detection) subject to the constraint that the transfer matrix function from faults to residual is equal to a pre-assigned diagonal transfer matrix (for isolation of possibly simultaneous occurring faults). Our solution is given in the form of linear matrix inequalities using state-space techniques, as well as a model matching problem using matrix factorisation techniques. A numerical example is given to illustrate the efficiency of the fault detection and isolation filter.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.