Abstract

Introduction: Observer variability is known in taking head circumference. Stretchable tapes do not provide accurate results after being used repeatedly. The aim of this study was to compare the intra-observer and inter-observer variability in measuring head circumference (HC) or occipito-frontal circumference (OFC) by using routine stretchable and non-stretchable tapes.Material and Methods: In this crosss-ectional study, all stable children in the age group of 1 month to 5 years attending the pediatric department of a tertiary care teaching hospital over six months period were included. The main outcome measures were: intra-observer & inter-observer variability in HC measurements by routinely used stretchable and non-stretchable tapes, and accuracy of readings of old stretchable tapes.Results: A total of 301 children were included. There was good correlation in the measurements taken by two observers (inter-observer), and three different readings of the same observer (intra-observer), correlation coefficient being > 0.99. With stretchable tape, 26% subjects had both intra-observer and inter-observer variability of ≥ 0.5 cm, which was 9.9% and 15.9% with the use of non-stretchable tape, respectively. Non-stretchable tape compared to stretchable tape had significantly less intra-observer (p < 0.001) and inter-observer variability (p=0.038).Conclusions: Observer variability was significantly less with the use of non-stretchable tapes compared to routinely used stretchable tapes. Old stretchable tapes used repeatedly over certain periods were not able to provide accurate readings.

Highlights

  • Observer variability is known in taking head circumference

  • The aim of this study was to find whether significant observer variability exists and whether use of non-stretchable tape can minimize the observer variability or not

  • Observed variability in clinical context: The intraobserver variability in the measurement of ≥0.5 cm using stretchable tapes was seen in 79 (26%) cases and using non-stretchable tapes was seen in 30 (9.9%) cases, the difference being significant (p < 0.001)

Read more

Summary

Introduction

Stretchable tapes do not provide accurate results after being used repeatedly. The aim of this study was to compare the intra-observer and inter-observer variability in measuring head circumference (HC) or occipito-frontal circumference (OFC) by using routine stretchable and nonstretchable tapes. The main outcome measures were: intra-observer & inter-observer variability in HC measurements by routinely used stretchable and non-stretchable tapes, and accuracy of readings of old stretchable tapes. 26% subjects had both intra-observer and inter-observer variability of ≥ 0.5 cm, which was 9.9% and 15.9% with the use of nonstretchable tape, respectively. Conclusions: Observer variability was significantly less with the use of nonstretchable tapes compared to routinely used stretchable tapes. Old stretchable tapes used repeatedly over certain periods were not able to provide accurate readings. There is need of a valid, precise, accurate, and reliable tool for OFC measurement in children.

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.