This paper addresses the subject of interturn short circuit estimation in the stator of a delta-connected induction motor. In this paper, an adaptive observer scheme is proposed. The proposed observer is capable of simultaneously estimating the speed of the motor, the amount turns involved in the short circuit, and an expression of the current in the short circuit. Moreover, the states of the motor are estimated, meaning that the magnetizing currents are made available even though a fault has occurred in the motor. To be able to develop this observer, a model that is particularly suitable for the chosen observer design, is also derived. The efficiency of the proposed observer is demonstrated by tests performed on a test setup with a customized designed induction motor. With this motor it is possible to simulate interturn short-circuit faults.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.