Abstract
PurposeIntensity modulated radiation therapy (IMRT) has allowed accurate delivery of prostate radiotherapy; Volumetric modulated arc therapy (VMAT) offers an advancement of this technique with possible dosimetric advantages and delivery in a shorter time than standard IMRT. We hypothesize that treatment duration is a controllable factor associated with intrafraction target motion. MethodsIncluded patients were treated for localized prostate cancer using IMRT or VMAT (RapidArc, Varian Medical Systems, Palo Alto, CA). Continuous motion data were monitored simultaneously using electromagnetic transponders (Calypso 4D Localization System, Calypso Medical Technologies, Inc, Seattle, WA). Displacements were recorded in the RL (right-left), SI (superior-inferior), and AP (anterior-posterior) directions at 10/second (Hz). Daily motion was reported as the mean (R̄̄) and 95th percentile (R95) displacement value for the entire session. Time effect was assessed by measuring daily displacement variables (R̄̄, R95) after each successive minute of treatment. ResultsThirty-seven patients were included, accounting for 1332 treatment sessions. Mean session time was 7.4 minutes (range, 0.5-37.2; interquartile range, 4.8-9.2). R̄̄ (0.06, 0.08, 0.11, 0.18) and R95 (0.14, 0.18, 0.23, 0.36) values (RL, SI, AP, 3-dimensional [3D], respectively) were evaluated for the entire cohort. Regression analysis showed treatment time to be the strongest predictor of observed displacements (P < .001 AP, SI, 3D; P < 0.05 RL). Ninety-five displacements increased continuously from 0.05 cm, 0.09 cm, 0.12 cm, and 0.16 cm after 1 minute to 0.21 cm, 0.20 cm, 0.29 cm, and 0.47 after 10 minutes (RL, SI, AP, and 3D). Mean session time for VMAT was 4.6 minutes compared to 8.4 minutes for IMRT (difference = 3.8 min, P < .0001); VMAT was associated with reduced motion for both (difference = 0.02, 0.03, 0.05, 0.07 cm) and (0.03, 0.04, 0.11, 0.12 cm) displacements. ConclusionOur study is unique in exploring the role of session duration on intrafraction motion in the setting of electromagnetic transponders as well as VMAT. Our main results demonstrate that observed intrafraction prostate motion during radiotherapy is greater with increasing session time. Additionally, VMAT, due to shorter treatment sessions, resulted in significant reduction (30%-40%) in intrafraction displacements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.