Abstract

Over 2000 buildings were surveyed by members of the Colegio de Ingenieros (CICM) and Sociedad Mexicana de Ingenieria Estructural (SMIE) in Mexico City following the Puebla-Morelos Earthquake of 2017. This inventory of surveyed buildings included nearly 40 collapses and over 600 buildings deemed to have structural damage. Correlation of damage with peak ground acceleration (PGA), peak ground velocity (PGV), predominant spectral period, building location, and building properties including height, estimated stiffness, and presence of walls or retrofits was investigated for the surveyed buildings. The evidence available suggests that (1) ground motion intensity (PGV) drove the occurrence of damage and (2) buildings with more infill and stiff retrofit systems did better than other buildings.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.