Abstract
An 80-year-old male patient with an acute myocardial infarction in the mid left anterior descending artery was treated with a BioFreedom stent (2.5 × 24 mm) (Biosensors Inc., Newport Beach, CA, USA). Thirty days post procedure, the patient was re-admitted with chest pain. A significant coronary artery stenosis in the mid left anterior descending artery more progressive than the previous one (not involving proximal stent-edge) was treated with percutaneous coronary intervention. Following this, optical frequency domain imaging of the BioFreedom stent revealed a fully expanded stent with complete stent apposition in its entire length and strut coverage with neointimal hyperplasia.<Learning objective: For patients with high bleeding risk, BioFreedom stent (Biosensors Inc., Newport Beach, CA, USA) may be considered a sufficiently effective device with shortened duration of dual antiplatelet therapy.>
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.