A novel non-destructive inspection method using terahertz waves for the detection of broken wires in copper cables shielded by insulating polymer opaque in the visible and near infrared light region is presented. Terahertz reflection imaging, using a 0.14THz IMPATT oscillator and a Schottky barrier detector, was applied to insulated copper cables that had been artificially damaged. The internal insulated wires embedded in the opaque polyethylene can be clearly visualized using THz radiation. It was shown that a gap in a wire can be detected by a decrease in the intensity of the reflected signal where the size of the gap is greater than the wavelength of the oscillator.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.