Abstract

The dynamic and electric field excitation method is a new advanced detection method. In this method, the observation frequency and of emission electrode must be reasonably selected according to the actual geological conditions of coal mine roadway to obtain the apparent frequency with adequate Induced Polarization (IP) information of geological anomalies and improve the measurement accuracy of the instrument. This paper completed the simulation of apparent frequency varying with the observation frequency and Cole-Cole model parameters with MATLAB software. The results show that the key to selecting the observation frequency mainly depends on the charge and discharge time constant .Then the paper analyzed the effect of the measured apparent frequency on the measurement accuracy. According to time constant values​​ of geological conditions in coal mine roadway, considering the efficiency and electromagnetic coupling effects on the measurement, it is best to select the observation frequency within a frequency range of 0.05~0.1Hz and the frequency ratio coefficient of 13 or 15. Now apparent IP effect is obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.