Abstract

We present the very first experiment allowing in situ observation of surface evolution during very high electric field application. This has been achieved by soft (/spl lambda/=21.2 nm) X-ray laser Fresnel two-mirror interferometry. The surface under study was a niobium planar cathode opposite to a stainless steel blade-like anode. The applied field range on the cathode was F/spl ap/0 to 50 MV/m. The interferograms were single shots of 80 ps duration, allowing to probe the surface morphology quasi-instantaneously. The delay between two shots was 20 min while the electric field was kept on. The comparison of successive interferograms gives the Nb surface evolution over /spl sim/2 h. Thus, we observed the appearance of defects of /spl sim/3 nm high and their evolution with time. These may be the precursors of the minute breakdown which occurred later on. This technique thus makes it possible to detect the preliminary stages of a discharge.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.