Abstract

Wearable thermoelectric generators can harvest heat from the human body to power an intelligent electronic device, which plays an important role in wearable electronics. However, due to the complexity of human skin, there is still no unified standard for performance testing of wearable thermoelectric generators under wearable conditions. Herein, a test platform suitable for a wearable thermoelectric generator was designed and built by simulating the structure of the arm. Based on the biological body temperature regulation function, water flow and water temperature substitute blood flow and blood temperature, the silicone gel with some thickness simulates the skin layer of the human arm, thus achieving the goal of adjusting the thermal resistance of human skin. Meanwhile, the weight is used as the contact pressure to further ensure the reliability and accuracy of the test data. In addition, the environment regulatory system is set up to simulate the outdoor day. Actually, the maximum deviation of the performance of the thermoelectric generator worn on the test platform and human arm is ∼5.2%, indicating the accuracy of objective evaluation.