Abstract

Changing the pre-exponential factor and the activation energy coefficient, the single-step reaction mechanism for hydrogen combustion was established, and the calculation and analysis of hydrogen combustion have been conducted by this mechanism. The results from the calculation and the experiment were compared, and the calculations of hydrogen combustion were processed in different hydrogen concentration by the single-step reaction mechanism. The results showed that the calculations and experimental flame propagation were conformable, and the modified single-step reaction mechanism for hydrogen combustion can be used to calculate and analyze the hydrogen combustion in nuclear power plants.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.