Abstract
The flashboard was installed in the circulation compartment of the modified oxidation ditch in order to regulate the mixed reflux from aerobic zone to anoxic zone. The differences of the nutrient removal efficiencies and the phosphate-removal bacteria content were researched before and after flashboard installation. The results showed that the average removal efficiencies of COD, NH4+, TN, TP were 93.3%, 87.1%, 78.1% and 96.0% respectively, and the proportion of denitrifying phosphate-removal bacteria (DPB) to total phosphorus accumulating organisms were 46.1% after the flashboard installation. However, the average removal efficiencies of COD, NH4+, TN, TP were 91.2%, 82.7%, 67.2% and 86.4% respectively, and the proportion of denitrifying phosphate-removal bacteria to total phosphorus accumulating organisms were 17.54% before the flashboard installation. So, the modified oxidation ditch with flashboard could enrich denitrifying phosphate-removal bacteria and and improve the nutrient removal efficiencies.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.