Abstract
In this study, natural convection from vertical cylinders with triangular fins was experimentally investigated with various fin numbers, fin heights, and base temperatures. From the experimental data, we propose a correlation for estimating the Nusselt number, which is applicable when the Rayleigh number, ratio of the fin height to fin length, and fin number are in the ranges of 1000–120,000, 0.2–0.6, and 9–72, respectively. Using this correlation, a contour map depicting the thermal resistance as a function of the fin number and fin thickness is presented. This contour map shows the existence of the fin number and fin thickness, at which the thermal resistance is minimized.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.